Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 141: 105787, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36989873

RESUMO

While cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone-implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical strength of the bone-implant interface by combining experimental and numerical approaches. Four rough (Sa = 24.5 µm) osseointegrated coin-shaped implants were left in sheep cortical bone during 15 weeks of healing time. Each sample was experimentally rotated at 0.03°/sec until complete rupture of the interface. The maximum values of the torque were comprised between 0.48 and 0.72 N m, while a significant increase of the normal force from 7-12 N to 31-43 N was observed during the bone-implant interface debonding, suggesting the generation of bone debris at the bone-implant interface. The experimental results were compared to an isogeometric finite element model describing the adhesion and debonding phenomena through a modified Coulomb's law, based on a varying friction coefficient to represent the transition from an unbroken to a broken bone-implant interface. A good agreement was found between numerical and experimental torques, with numerical friction coefficients decreasing from 8.93 to 1.23 during the bone-implant interface rupture, which constitutes a validation of this model to simulate the debonding of an osseointegrated bone-implant interface subjected to torsion.


Assuntos
Prótese Ancorada no Osso , Implantes Dentários , Animais , Ovinos , Osseointegração , Fenômenos Mecânicos , Interface Osso-Implante , Próteses e Implantes , Análise de Elementos Finitos , Fenômenos Biomecânicos
2.
J Biomech ; 46(6): 1162-8, 2013 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-23352649

RESUMO

The use of tricalcium silicate-based cement (TSBC) as bone substitute material for implant stabilization is promising. However, its mechanical behavior under fatigue loading in presence of a dental implant was not reported so far because of the difficulty of measuring TSBC properties around a dental implant in a nondestructive manner. The aim of this study is to investigate the evolution of the 10 MHz ultrasonic response of a dental implant embedded in TSBC versus fatigue time. Seven implants were embedded in TSBC following the same experimental protocol used in clinical situations. One implant was left without any mechanical solicitation after its insertion in TSBC. The ultrasonic response of all implants was measured during 24 h using a dedicated device deriving from previous studies. An indicator I based on the temporal variation of the signal amplitude was derived and its variation as a function of fatigue time was determined. The results show no significant variation of I as a function of time without mechanical solicitation, while the indicator significantly increases (p<10(-5), F=199.1) at an average rate of 2.2 h(-1) as a function of fatigue time. The increase of the indicator may be due to the degradation of the Biodentine-implant interface, which induces an increase of the impedance gap at the implant surface. The results are promising because they show the potentiality of ultrasonic methods to (i) investigate the material properties around a dental implant and (ii) optimize the conception of bone substitute materials in the context of dental implant surgery.


Assuntos
Cimentos Ósseos , Compostos de Cálcio , Implantes Dentários , Silicatos , Acústica , Análise do Estresse Dentário , Estresse Mecânico
3.
J Clin Monit Comput ; 17(3-4): 259-67, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12455745

RESUMO

New methods of data processing combined with advances in computer technology have revolutionized monitoring of patients under anesthesia. The development of systems based on analysis of brain electrical activity (EEG or evoked potentials) by neural networks has provided impetus to many investigators. Though not claiming to be the end-all in patient monitoring, the potential and efficiency of the combination does indeed stand out. Various strategies are presented and discussed, as well as suggestions for further investigation.


Assuntos
Monitorização Fisiológica , Redes Neurais de Computação , Anestesia , Eletroencefalografia , Potenciais Evocados , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...